Abstract:Objective Curve of sodium and ultrafiltration curve to prevent the occurrence of hypotension during hemodialysis.MethodsLooking back to our hospital for hemodialysis patients.All the patients were divided into control group and observation group.The two groups in gender,age,illness,etc.There was no significant difference between comparable.Control group in the conventional mode of dialysis,the observation group using sodium curve and the curve pattern ultrafiltration dialysis.Two groups were compared at different times of the changes in blood pressure,low blood pressure the number of cases and the number of patients,the decline in blood volume and the amount of ultrafiltration.Results3 h and 4 h observation group than the control group changes in blood pressure stability,Number of cases of hypotension and the number of significantly less than the control group,Decreased blood volume, and ultrafiltration was significantly lower than the control group,the significant difference.ConclusionCurve of sodium and ultrafiltration curve model can improve the patient's tolerance,the prevention of hypotension,is conducive to fully dehydrated,it is widely used in clinical.
|